The cooling capacity of a single unit ranges from 25 to 300 tons, and multiple units can be combined

Closed-loop circulation ensures clean medium and is not prone to scaling

Energy and water conservation, supporting the operation of a low-energy consumption economic model in winter

It can replace water chillers in winter, greatly reducing energy consumption

Imported material shell, super anti-corrosion, suitable for all kinds of harsh environments

The self-draining heat exchange coil during shutdown is convenient for anti-freezing protection in winter.

The cooler is located entirely beneath the pre-cooled packing. The equipment has a low center of gravity, is stable and vibration-resistant, and can be inspected and flushed from the outside

The pre-cooled packing is designed with advanced technology and has an extremely low drift rate. The cooling temperature is closer to the ambient wet-bulb temperature

It effectively reduces the scaling rate on the outer surface of the coil, and high-temperature resistance of 50℃/60℃ is available as an option

The water distribution method is uniform and reasonable, with efficient heat exchange and less prone to clogging

Large-sized inspection doors and internal inspection passages facilitate access for internal maintenance and cleaning

Applicable media: water, oil, formaldehyde, quenching fluid, and other process circulating cooling media

2025
-
04
-
30
null

The cooling capacity of a single unit ranges from 5 to 300 tons, and multiple units can be combined

Closed-loop circulation ensures clean medium and is not prone to scaling

Energy-saving and water-saving, it supports a dry operation mode without spray in winter

It can replace water chillers in winter, greatly reducing energy consumption

Imported material shell, super anti-corrosion, suitable for all kinds of harsh environments

The self-draining heat exchange coil during shutdown is convenient for anti-freezing protection in winter

Pure coil cooling can accept high-temperature water inflow without worrying about the temperature limit of PVC packing

The water distribution method is uniform and reasonable, with efficient heat exchange and less prone to clogging

Support the winter mixed fresh air operation mode without white fog

Multiple optional additional configurations such as low noise, variable frequency speed control, and explosion-proof treatment are available

Applicable media: water, oil, formaldehyde, quenching fluid, and other process circulating cooling media
2025
-
04
-
30
null
  • 1. Explosion-proof safety design

    Explosion-proof electrical system: explosion-proof motors, explosion-proof junction boxes and explosion-proof control cabinets are used, which comply with ATEX/Ex certification standards to avoid explosions caused by electric sparks. Antistatic material: The tower body is made of flame-retardant and antistatic composite materials to eliminate the risk of static electricity accumulation. Enclosed structure: Strengthened sealing design to prevent flammable gases from penetrating into the equipment.
  • 2. Corrosion resistance

    The shell and heat exchange tubes are made of stainless steel or fiberglass, which can withstand corrosive media in chemical, oil and gas environments.
  • 3. Intelligent monitoring and alarm

    Integrated combustible gas detection sensors, linked sound and light alarms and automatic shutdown functions to ensure the safety of high-risk areas.
  • 4. Efficient heat exchange

    The closed structure reduces water pollution and improves heat exchange efficiency.
  • 5. Energy saving and environmental protection:

    The circulating water system reduces water consumption, and intelligent control reduces energy waste.
  • 6. Modular design

    Supports multi-tower parallel connection to meet different scale requirements.
  • 7. Application scenarios

    Industrial environments with flammable and explosive gases such as petrochemical, natural gas processing, and pharmaceutical workshops.
  • 2025
    -
    04
    -
    30
    null
  • 1. Efficient anti-corrosion design

    Corrosion-resistant materials: core components (such as heat exchange coils and shells) are made of stainless steel (304/316L), titanium alloy or aluminum-magnesium plated steel plates to resist acid, alkali, salt spray and corrosive gases. Surface treatment technology: hot-dip galvanizing, plastic spraying or nano-ceramic coating technology is used in key parts to extend the service life of equipment in harsh environments. Fully enclosed structure: The circulating medium (such as water and ethylene glycol solution) is completely closed to avoid contact with external pollutants and reduce corrosion sources.
  • 2. Advantages of closed circulation system

    Zero pollution of the medium: Prevent debris and dust from entering the circulation system, suitable for precision industries (such as semiconductors and pharmaceuticals) and fields sensitive to water quality. Water-saving and environmental protection: Spray water is only used to assist heat dissipation, with low evaporation loss, reducing water resource waste and meeting green environmental protection standards. Stable operation: The closed design avoids scaling and clogging of the medium, maintains high-efficiency heat transfer performance for a long time, and reduces maintenance frequency.
  • 3. Efficient heat dissipation and energy saving

    Composite heat exchange technology: Combining coil dry cooling and spray water evaporation heat dissipation, it still maintains excellent cooling efficiency under high temperature conditions. Intelligent frequency conversion control: According to the changes in ambient temperature, humidity and load, the fan and spray pump speed are automatically adjusted to save energy by more than 30%. Optimized air duct design: Adopt high-efficiency and low-noise axial flow fans, combined with aerodynamic guide structures, to improve heat dissipation efficiency and reduce energy consumption.
  • 4. Modularization and customization

    Flexible configuration: supports multi-module parallel connection to meet cooling needs of different scales and convenient expansion. Environmental adaptability: customizable anti-corrosion grade, temperature resistance range (-40℃~80℃) and explosion-proof design, adapting to extreme scenarios such as chemical industry and metallurgy. Compact structure: small footprint, supports indoor/outdoor installation, and adapts to factory layout with limited space.
  • 5. Long life and low maintenance cost

    Double anti-corrosion protection: material and coating synergistic protection, equipment life can reach more than 15 years, reducing replacement costs. Modular replacement: damaged parts can be replaced separately, reducing downtime and maintenance costs. Low chemical dependence: Closed circulation reduces scale generation, reduces the use of chemical agents, and saves operating costs.